Once again, new update of DOPSoft 1.00.07.
DOPSoft will be in near future the only one Delta HMI software so I recommend to everybody to take a look on this new version.
New image and many problems corrected to have finally a very stable product.
Check the new changes on the following announcement
Feel free to download the complete version FOR FREE on our website
DOPSOFT 1.00.07
eSERVER 1.00.17
eREMOTE 2.00.03
or on our FTP all at once
HMI Delta Suite May_2012
And Enjoy.
March 23, 2016 at 5:55 pm
Greetings .
Anyone can help me I need to control several plc siemens s7 200 with a single screen Hmi delta through the serial port 485 , as would be the prog plc and screen.
Thank you for your help
April 8, 2015 at 9:45 am
is profibus compatible with Delta HMIs.i want to communicate the siemens s7300 plc with delta hmi via profibus.? or any other options for communication with profibus.
October 13, 2014 at 11:07 am
Do you have an English version of dopsoft1.00.07385 for downloading?
September 2, 2014 at 2:38 pm
Hi, Please also help me to communicate between a DOP HMI and S7-1200.
And any other helpful info you may have. thanks
July 24, 2013 at 5:51 pm
Hi. I’m having trouble to comunicate a DOP HMI with a S7-1200. Do you have an example program or some info about it?
February 26, 2013 at 9:24 am
hi please provide us the communication programme of siemens s71200 with delta hmi
October 18, 2012 at 9:51 am
Greetings of the day!
I need some information regarding printer attachment with HMI.
First of all I want to tell you about my application and requirement.
I am using the DOP-B10E615 HMI and my screen size is 1024×600.
I want to print an screen with same size successively after each process cycle. The list of printers default provided in software is quite OLD for printer industry, it is very difficult to arrange them..
My point of assistance are:
1. What is the best printer suited for this page size?
2. Can we use any printer of the same manufacturer such as Epson any lazer printer, if not then I request you to give me list of printers we can use?
3. Can we print a screen successively after each cycle automatically regardless of the present HMI page?
4. Is there any sequence which have to be written in macros? If yes, then it is requested to provide it.
Regards & Thanks
M.M.Saifi
September 17, 2012 at 3:39 am
I’ve been using the DOPSoft and have found a problem when setting the HMI in “Modbus Slave” mode.
With Screen Editor I could set the HMIStation number but in DOPSoft this is disabled.
September 17, 2012 at 11:24 am
Did you try to unable the default mark?
August 30, 2012 at 11:20 pm
Hello Delta, when I try to download or upload data from screen edit via Ethernet i received a error message “can’t open Ethernet” it is something that I’m missing on the configuration?
thank you.
August 25, 2012 at 11:50 pm
Good afternoon!
I wonder how do I communicate a DOP-B HMI with Ethernet in a clp siemens S7-1200, because I can not do both talk!
Thank you!
August 26, 2012 at 2:21 am
It works!
It must be using Ethernet HMI.
August 8, 2012 at 2:50 pm
Hello Delta.
Thank You for your help.
When I try to control the HMI by the newest eRemote 2.00.03 an error message appears: “Did not support rotation of elements!”
Please when can I find an old version that support that function?
August 8, 2012 at 4:41 pm
No new or older version supports rotation on eRemote.
Our engineers are working on it, sorry for inconveniences.
June 28, 2012 at 5:50 pm
hi delta ,
i have a dop-b 07s201 with firmware 2.0122
and my laptop dont install the drivers my version of dop soft is the lastest with the patch for series b07s
June 22, 2012 at 6:06 am
Dear Sir,
i have an .exe file developed on visual basic. i want to transfer this file on Delta HMI. how can i do this task?
please replay on earliest.
Thanks
June 22, 2012 at 12:01 pm
Our HMI do not have OS DOS runtime operative system.
So it will never works
June 16, 2012 at 7:30 am
Does it DELTA HMI can communicate with another plc brand over ethernet/profinet?
June 18, 2012 at 8:50 am
Profinet or profibus protocols are not compatible with Delta HMIs.
But Delta HMI works with S7200 and S7300 via MPI, and Delta Ethernet models works with S71200 with no problem.
January 22, 2013 at 8:28 am
could you please send me a sample communication program between Delta HMI(DOP-B10E615) and Siemens S7-1200 using Ethernet
January 22, 2013 at 10:03 am
sure, I look If I found some example on my library and Ill post it
May 24, 2012 at 10:23 pm
me gustaria poder enlazarme ala pantalla con el eremote 2.00.03 desde otra parte, lo hize con la red local y funciona perfectamente, tambien probe conectandome a un equipo remotamente y abrir el programa y funciona, ahora solo quiero conectarme a al pantalla sin tener una computadora cerca de la pantalla solo con el eremote agradeceria mucho su ayuda.
May 25, 2012 at 11:01 am
Dear Walter,
Please write your question in english.